CHANGZHOU FHD ELECTRONICS CO.,LTD
|
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
5V SMT Buzzer Element , Electro-Magnetic SMD Piezo Transducer
Quick Detail:
Description:
1. Technical Parameter
Measuring condition
Part shall be measured under a condition (Temperature: 535, Humidity: 45%85%R.H., Atmospheric pressure: 860 1060hPa) unless the standard condition (Temperature: 25±3, Humidity: 60±10%R.H. Atmospheric pressure: 860 1060hPa) is regulated to measure.
1 |
Rated Voltage |
5 VDC |
2 |
Operating Voltage |
3 – 7 VDC |
3 |
Rated Current |
Max.10mA, at 5VDC |
4 |
Sound Output at 10cm |
Min.80 dB, at 5VDC |
5 |
Resonant Frequency |
4000±500 Hz |
6 |
Tone |
Continuous |
7 |
Operating Temperature |
-20 - +70 |
8 |
Storage Temperature |
-30 - +80 |
9 |
RoHS |
Yes |
10 |
Weight |
Approx 1.0g |
*Housing Material: Black PPS
Surface mounting condition
(1)Reflow soldering
Recommendable reflow soldering condition is as follows.
Note:
(2)Soldering pattern
Reliability Test
After any following tests the part shall meet specifications without any degradation in
appearance and performance except SPL. SPL shall not deviate more than -10 dB
from the initial value
(1)Ordinary Temperature Life Test
The part shall be subjected to 96 hours at 25±10. Input rated voltage
Resonant frequency, 1/2 duty Square wave.
(2)High Temperature Test
The part shall be capable of with standing a storage temperature of +80 for 96 hours.
(3)Low Temperature Test
The part shall be capable of with standing a storage temperature of -30 for 96 hours.
(4)Humidity Test
Temperature:+40±3 Relative Humidity:90%95% Duration: 48 hours
and expose to room temperature for 6 hours
(5)Temperature Shock Test
Temperature:60 /1hour→ 25/3hours→-20/1hour→ 25/3hours (1cycle)
Total cycle: 10 cycles
(6)Drop Test